Trace every instruction
Guidelines inform clinical decisions; primary trials document tested methods; device instructions define model-specific operation. Each source is labelled by type.
CTDSCTDS reference library · Reviewed 17 October 2026
Explore clinical guidance, targeting methods, coil-specific evidence and safety references in one place.
Guidelines inform clinical decisions; primary trials document tested methods; device instructions define model-specific operation. Each source is labelled by type.
Record the measured motor hotspot and the coil used for MT. Scalp landmarks, helmet reference marks and intended brain regions are different pieces of information.
H7 depression placement and exact deep-coil fitting/orientation remain pending applicable device documentation. Source dates are not a guarantee of current regulatory status.
Browse the evidence
24 of 24 sources
Source already cited in the CTDS workflow. Consult the full publication and its scope.
Read original source ↗Source already cited in the CTDS workflow. Consult the full publication and its scope.
Read original source ↗Source already cited in the CTDS workflow. Consult the full publication and its scope.
Read original source ↗Source already cited in the CTDS workflow. Consult the full publication and its scope.
Read original source ↗Source already cited in the CTDS workflow. Consult the full publication and its scope.
Read original source ↗Source already cited in the CTDS workflow. Consult the full publication and its scope.
Read original source ↗Source already cited in the CTDS workflow. Consult the full publication and its scope.
Read original source ↗Source already cited in the CTDS workflow. Consult the full publication and its scope.
Read original source ↗Source already cited in the CTDS workflow. Consult the full publication and its scope.
Read original source ↗Source already cited in the CTDS workflow. Consult the full publication and its scope.
Read original source ↗Source already cited in the CTDS workflow. Consult the full publication and its scope.
Read original source ↗Motor hotspot localization and hand/leg assessment; §3.3.1 informs the resting EMG relative-frequency tracker in tab 3. Diagnostic guidance must be reconciled with the applicable therapeutic device protocol.
Read original source ↗H1 position: 6 cm anterior to the motor hotspot using the cap ruler. Trial: 18 Hz, 120% resting MT, 55 × 2-second trains, 20-second intertrain interval, 1,980 pulses.
Read original source ↗H7 position: 4 cm anterior to the foot motor reference. Trial: 20 Hz, 100% leg resting MT, 50 × 2-second trains, 20-second intertrain interval, 2,000 pulses; individualised symptom provocation.
Read original source ↗Identify the helmet position activating the right abductor pollicis brevis; align the helmet symmetrically and move 6 cm anteriorly. Trial: 10 Hz, 120% MT, 1,800 pulses; smoking-cue provocation.
Read original source ↗Background on H7 geometry and applications. This 2021 review is not a current operator manual or a complete record of current indications.
Read original source ↗US clearance for adjunctive adult OCD treatment. Cool D-B80 for both leg MT and treatment; bilateral dmPFC, 20 Hz, 100% leg MT, 2,000 pulses. Substantial equivalence to H7, without a new D-B80 pivotal OCD trial. Handle orientation is not specified.
Read original source ↗Describes a prefrontal treatment position 4 cm anterior to leg motor cortex. Field distributions differ between coils; regulatory equivalence does not make their physical positioning interchangeable.
Read original source ↗September 2025 US update includes Cool D-B80, Cool-B70 and Cool-B65 for MDD and OCD. Indication compatibility alone does not specify placement; check applicable regional labelling and IFU.
Read original source ↗Background reference already linked in tab 4; orientation must match the target, coil and protocol.
Read original source ↗Reference already linked in tab 4. Navigation guidance concerns both position and orientation, with appropriate registration and calibration.
Read original source ↗Educational synthesis of the regulatory and published placement sources. Includes the leg motor reference and 4 cm anterior localization. Exact handle orientation requires manufacturer IFU verification; this is not an operator manual.
Open reference PDF ↗Source already cited in the CTDS workflow. Consult the full publication and its scope.
Read original source ↗Basis for the symptom categories in tab 4. The adapted web form is not a validated questionnaire and does not determine causality or permission to continue treatment.
Supplied form · no public source linkCurated for the Clinical TMS Decision Support and Placement Tool by Dr Jithin T Joseph. This page brings together the sources cited across tabs 1–5 and the coil-placement documents reviewed for CTDS. It is a selected reference collection, not a systematic review or validated decision rule.
The post-session form is adapted from the supplied TMS AEQ. Source inclusion does not imply endorsement by manufacturers, authors or professional organisations. Consult original documents for eligibility, exclusions, safety requirements and full protocol details.
Last content review: 17 October 2026. Updates require clinical review; the library does not automatically monitor changes.